Operating Instructions3-348-636-026/5.04SI 232-II, BD 232 Interface Adapterwith METRAwin 10 / METRA Softwarefor Measuring and Recording Systems with M
10 GOSSEN METRAWATT GMBH5.2 DisplayFigure 4.3 Memory Adapter LCD1 Digital DisplayThe current menu item appears at the 7 segment liquid crystal display
GOSSEN METRAWATT GMBH 115.3 Switching the Memory Adapter ON and OFFBriefly press the right-hand ON/OFF key in order to switch the memory adapter ON.Th
12 GOSSEN METRAWATT GMBH6 Operating Instructions at a GlanceThe memory adapter can be operated with the keypad on the device, or more conveniently wit
GOSSEN METRAWATT GMBH 136.3 Shortcuts at the Multimeter • Select Normal Operation– Switch the device off, and then back on.– Or, if the device is in t
14 GOSSEN METRAWATT GMBH6.4 Menus Overview Test4mm:sshh:mmddmm:sshh:mmddmm:sshh:mmddmm:ssYESno38400noModEMnnnnnHirAtE HYSt triG CYCLE tIME Addr bd-ouS
GOSSEN METRAWATT GMBH 157 Menu Item Descriptions7.1 Set Sampling Rate – rAtEKey Sequence: SEt rAtE m:ss.hh Settings: m = minutes, ss = seconds,
16 GOSSEN METRAWATT GMBH7.3 Trigger Settings – triGThe trigger setting determines which multimeter measurement values will be stored to the adapter. B
GOSSEN METRAWATT GMBH 17• Disabling the TriggerKey Sequence: SEt ... ... trIG oFF tiME oFF Settings: triG = oFF, the trigger is disabled•
18 GOSSEN METRAWATT GMBH7.4 Recording: Duration and Type – durA, CYCLE• Recording without Time Limits – durAKey Sequence: SEt ... ... durA on
GOSSEN METRAWATT GMBH 197.7 Set Transmission Speed – bAud-ou, bAud-in• Set Transmission Speed to the PC – bAud-ouKey Sequence: SEt ... ... bAud-
2 GOSSEN METRAWATT GMBHContents Page1 Introduction ...
20 GOSSEN METRAWATT GMBHStart manual data recording:Shortcut: Press and hold the yellow ESC key and press the key once for each desired measurement.
GOSSEN METRAWATT GMBH 21• View Individual, Recorded Measurement ValuesKey Sequence: rECAll bbbb StAt SEE (bEGin) ... nnnnn1 ... nnnnnm ... (E
22 GOSSEN METRAWATT GMBH7.10 Reading Out Data from the Adapter at the PC / Parameter Configurations – PCKey Sequence: PC PC-nnSettings: nn = selected
GOSSEN METRAWATT GMBH 23 Figure 4.5 LCD Test• Internal Memory TestKey Sequence: InFO tiME tESt diSP rAM no YES buSYSettings: no = no memory
24 GOSSEN METRAWATT GMBH8 METRAwin 108.1 Installing METRAwin 10WINDOWS version 3.1 or higher is required for installation.METRAwin 10 is installed aut
GOSSEN METRAWATT GMBH 259 Memory Adapter Technical DataSupported Measuring InstrumentsMETRAHit 12S ... 16S, 16I/T, 18S, 14A, 22S/M ... 29SOperating El
26 GOSSEN METRAWATT GMBHPower Supply:2 ea. 1.5 V mignon cellsDry cell per IEC R6 type 3006: 1100 mAhAlkaline-manganese per IEC LR6 type 4006: 2300 mAh
GOSSEN METRAWATT GMBH 2710 Repair and Replacement Parts ServiceDKD Calibration Lab and Rental Instrument ServiceWhen you need service, please contact:
GOSSEN METRAWATT GMBHThomas-Mann-Str. 16-2090471 Nuremberg, GermanyPhone +49-(0)-911-8602-0Fax +49-(0)-911-8602-669E-Mail: [email protected]
GOSSEN METRAWATT GMBH 31 IntroductionInterface AdapterWhereas interface adapter BD232 allows for online transmission of measured values from multimete
4 GOSSEN METRAWATT GMBH3 Multimeter, Adapter and METRAwin 10 Operating Modes3.1 General Information• The address for the adapter and its corresponding
GOSSEN METRAWATT GMBH 53.4 Configuring Multimeter Parameters– for all METRAHit 2x with SI232-II or BD232 3.5 Receiving Live Measurement Data from the
6 GOSSEN METRAWATT GMBH3.6 Saving Measurement Data to the SI232/-II Memory AdapterThe memory adapter can be used with all multimeter versions. Excepti
GOSSEN METRAWATT GMBH 74 Adapter Connection and Initial Start-Up4.1 Connecting the AdapterThe screw connections between the stacked adapters serve exc
8 GOSSEN METRAWATT GMBH➭ After selecting the “File/Measure” menu item, the recorded measurement values are transmitted to the PC and are displayed at
GOSSEN METRAWATT GMBH 95 Operating Elements, Switching the Adapter ON and OFF, Replacing the Batteries5.1 Keypad, InterfaceFigure 4.2 Memory Adapter O