Operating Instructions
GL SpectroSoft
Operation And Evaluation Software 1/06.14
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - GL SpectroSoft

Operating Instructions GL SpectroSoft Operation And Evaluation Software 1/06.14

Pagina 2

GOSSEN Foto- und Lichtmesstechnik GmbH 10 3. MAVOSPEC - WiFi - connect via WiFi Driver TCP connection via WiFi. Set IP address of a MAVOSPE

Pagina 3

GOSSEN Foto- und Lichtmesstechnik GmbH 11 4. MAVOSPEC - USB - connect via Android USB Driver The connection is done via USB cable. Android U

Pagina 4

GOSSEN Foto- und Lichtmesstechnik GmbH 12 2.2 Changing or Extending License Select File->Licence from main menu to extend software function

Pagina 5

GOSSEN Foto- und Lichtmesstechnik GmbH 13 Additional Function License To add new functionality to your software: 1. Connect the device and make

Pagina 6

GOSSEN Foto- und Lichtmesstechnik GmbH 14 3 Startup Measurement and analysis using GL SPECTROSOFT Startup 1. Connect your measuring instrumen

Pagina 7

GOSSEN Foto- und Lichtmesstechnik GmbH 15 4 Basic Function Tool Bar The different functions are accessible depend on the version / license of th

Pagina 8

GOSSEN Foto- und Lichtmesstechnik GmbH 16 11. Transmition/Refectance mode This mode allows to make comparative measurements. Reference mesurem

Pagina 9 - Selected device

GOSSEN Foto- und Lichtmesstechnik GmbH 17 4.1 Serial measurements GL_SpectroSoft allows to program the serial measurements with defined inter

Pagina 10

GOSSEN Foto- und Lichtmesstechnik GmbH 18

Pagina 11

GOSSEN Foto- und Lichtmesstechnik GmbH 19 5 Top Menu Options In the upper left corner of the screen you will find the access to remaining menu

Pagina 12

GOSSEN Foto- und Lichtmesstechnik GmbH 2 Thank you for selecting this state of the art GOSSEN product. We hope you are enjoying the easy operatio

Pagina 13

GOSSEN Foto- und Lichtmesstechnik GmbH 20 5.2 ISO 3664 Assessment ISO 3664 assessment - it is a measuring procedure according to ISO 3664:2000

Pagina 14

GOSSEN Foto- und Lichtmesstechnik GmbH 21 4. Place the GL SPECTIS 1.0 in the shown place and Click the icon twice to make measurement. The progra

Pagina 15

GOSSEN Foto- und Lichtmesstechnik GmbH 22 5.4 Action See basic functions tool bar 5.5 Window Save desktop - save a current desktop layout

Pagina 16

GOSSEN Foto- und Lichtmesstechnik GmbH 23 6 Measurements Result Windows 6.1 Measurement Measurement includes the results for each wavelength

Pagina 17

GOSSEN Foto- und Lichtmesstechnik GmbH 24 6.3 Results Results window contains the results of measurement in accordance with CIE 1931 2 ° observer

Pagina 18

GOSSEN Foto- und Lichtmesstechnik GmbH 25 6.4 Chart Chart window is a set of graphs representing chromacity diagrams determined by the CIE. Book

Pagina 19

GOSSEN Foto- und Lichtmesstechnik GmbH 26 Now you can select template containing set of parameter which will be shown in the selected results

Pagina 20

GOSSEN Foto- und Lichtmesstechnik GmbH 27 X2 Y2 Z2 X10 Y10 Z10 The list of codes which can be used in selected results template file (dependin

Pagina 21

GOSSEN Foto- und Lichtmesstechnik GmbH 28 6.6 Comparison Table Comparison table allow to compare spectrometric values of many measurements in on

Pagina 22

GOSSEN Foto- und Lichtmesstechnik GmbH 29 7 TOOLS 7.1 Bin Editor Binning groups can be defined by Bin Editor tool (Tools->Bin Editor) In

Pagina 23

GOSSEN Foto- und Lichtmesstechnik GmbH 3 GL SPECTROSOFT PRO is an operation and evaluation software for MAVOSPEC with an enhanced range of fu

Pagina 24

GOSSEN Foto- und Lichtmesstechnik GmbH 30 Definition of binning groups may be saved to or load form a text file. Software always use the last use

Pagina 25

GOSSEN Foto- und Lichtmesstechnik GmbH 31 Brightness groups are stored in similar way. You can edit them, save and load using the second tab in B

Pagina 26

GOSSEN Foto- und Lichtmesstechnik GmbH 32 When binning and brightness groups are defined, the appropriate names are presented in results window a

Pagina 27

GOSSEN Foto- und Lichtmesstechnik GmbH 33 7.2 Pass/Fail Editor Pass/Fail tool (Tools->Pass/Fail Editor) allows to define user conditions wh

Pagina 28

GOSSEN Foto- und Lichtmesstechnik GmbH 34 After measurement in results window and comparison table pass/fail check results are presented. Each pa

Pagina 29

GOSSEN Foto- und Lichtmesstechnik GmbH 35 8 Reports A report template is a text file in HTML format. It can be created in any text or HTML. A ge

Pagina 30

GOSSEN Foto- und Lichtmesstechnik GmbH 36 Printed in Germany – Subject cha

Pagina 31

GOSSEN Foto- und Lichtmesstechnik GmbH 4 Contents Page 1 Introduction 5 1.1 System Requirements 5 1.2 License Types 6 2 Installation 7 2.1

Pagina 32

GOSSEN Foto- und Lichtmesstechnik GmbH 5 1 Introduction GL SpectroSoft is optional evaluation software with an intuitive user interfa

Pagina 33

GOSSEN Foto- und Lichtmesstechnik GmbH 6 1.2 License Types The GL SPECTROSOFT software is available in three versions: BASIC, PRO and LAB. You c

Pagina 34

GOSSEN Foto- und Lichtmesstechnik GmbH 7 1 PRO license is an upgrade of BASIC and includes all features of BASIC and a complete set of addition

Pagina 35

GOSSEN Foto- und Lichtmesstechnik GmbH 8 To start the installation simply run setup GL_SpectroSoft v----.exe program from your CD. The installati

Pagina 36

GOSSEN Foto- und Lichtmesstechnik GmbH 9 2.1.1 GL SPECTROSOFT for GL SPECTIS Only GL_Spectrosoft is installed when you want to use devices usin