GOSSEN Foto- und Lichtmeßtechnik 12
2.7 Function TIMER
A timer function is provided in the Digiflash,
useful for long exposure or other timings
ranging from one second to thirty minutes.
Use the function button to select the
function TIMER and hold it down until the
OK-signal sounds. The display shows the
last value used. The read-out will show
the "minutes" and will flash to allow the
countdown timer to be adjusted.
Use the key M to enter the desired time
in minutes.
Confirm by pushing the function button.
The read-out "seconds" in the display
will flash.
Enter the "seconds" of the desired length
of time. Confirm by pressing and holding
the function button until the OK-signal will
sound. The timer will now be in the Start/
Stop function.
Push the key M to start the timer.
The display will show the remaining time
of the count-down. In addition to that,
during the last 10 seconds of the count-
down, interrupted signals can be heard.
At the end of the set time, a continued
signal will sound.